Zanussi CH60 Ventilation Hood User Manual


 
10
INSTALLATION INSTRUCTIONS
Technical information
DIMENSIONS HEIGHT OF CANOPY: 270mm
HEIGHT OF CHIMNEY:(UPPER SECTION) 215mm
(LOWER SECTION) 530mm
WIDTH OF CANOPY: CH 60 598mm
CH 90 898mm
DEPTH OF CANOPY: 490mm
ELECTRICAL SUPPLY VOLTAGE: (~50Hz) 220-240V
POWER CONSUMPTION: 225W
FAN MOTOR: 145W
LAMPS: (2 x40W) 80W
SUITABLE FOR -
INSTALLATION ABOVE: ELECTRIC HOB: 7KW (MAX)
GAS HOB: 10KW (MAX)
SLOT-IN ELECTRIC COOKER: 12.4KW (MAX)
SLOT-IN GAS COOKER: 13.5KW (MAX)
THIS APPLIANCE MUST BE EARTHED
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
Note: CE Marking certifies that this appliance complies with the
requirements laid down in EEC directive 89:336 (Electromagnetic
compatibility) and subsequent modifications and Low Votage directive
72/23/E.
This appliance is fitted with a 3 core mains cable
and must be permanently connected to the
electricity supply via a double-pole switch having
3mm minimum contact gap on each pole. A
Switched Fuse Connection Unit to BS.1363 Part
4, fitted with a 3 Amp fuse, is a recommended
mains supply connection accessory to ensure
compliance with the Safety Requirements
applicable to fixed wiring instructions.
This appliance conforms to BS.800:1988 and
EEC Directive No. 78 308 regarding suppression
of radio and television interference.