A: Built-in Electric Hob: 650mm minimum clearance
B: Built-in Gas hob: 700mm minimum clearance
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker: 787mm minimum clearance
Hob
Clearance Height
A minimum clearance height of 650mm (25
1
/
2
”) is
required when installed above a built-in electric hob, or
700mm (27
1
/
2
”) when installed above a built-in gas hob.
A minimum clearance height of 685mm (27”) is required
when installed above a slot-in electric oven, or 787mm
(30
1
/
2
”) when installed above a slot-in gas oven.
When installed between adjoining wall cabinets, the wall
cabinets must not overhang the hob and the distance
between the underside of the cabinet and the worktop
must be 450mm. If the height of the wall cabinet is less
than 450mm, a gap of 50mm must be maintained either
side of the hob.
This cooker hood must not be installed above
a cooking appliance with a high level grill.
Unpacking
The fittings supplied to install this cooker
hood can be found with the instruction book
inside the packaging and consists of the following:
Ducting spigot
Blanking plate
Wall fitting template
Fitting Kit: 2 - Wall fixing brackets
4 - Plastic rawl plugs
4 - Wall bracket fixing screws
2 - Security washers
2 - Security nuts
Fitting the Wall Brackets
1. Using the paper template provided mark the hole
positions on the wall for the bracket fixing screws.
2. Check that the hole differences are correct with
a tape measure as stated on the template.
3. At this stage it is important to allow 15mm (
1
/
2
”)
clear space above the cooker hood to enable it
to be hooked onto the brackets and for
subsequent removal for decorating or servicing.
4. Fit the brackets with the round ends facing
downwards using the plastic rawl plugs and
screws provided.