Zanussi ZCG 6200 Oven User Manual


 
6. PRESSURE TESTING
1 The oven injector is used as a pressure test point.
Remove the oven furniture. Remove oven burner box retaining clips (one spring clip from each side) and
remove box front cover. Replace one clip back into the right hand side of the burner box.
Remove oven burner by removing the spring clip from the right hand side of the oven burner and slide
burner off injector, whilst easing it forward and taking care not to strain the F.S.D. phial.
2. Connect the pressure gauge to the oven injector.
3. Check the supply pressure by turning the thermostat on and one hotplate tap full on and light the
appropriate burner. The pressure should be either:-
(i) For Natural Gas 20mbar
(ii) For LP.Gas The pressure must be set to 28 mbar for use on butane or 37
mbar for use on propane.
4. Turn off the taps, disconnect the pressure gauge and replace oven burner and cover, ensuring that the
F.S.D. phial is correctly located into the bracket on the burner.
5. Check operation of oven.
7. CHECKING THE GRILL
Place the grill pan containing the trivet into the grill compartment. Light the grill burner by turning the grill tap
full on and pressing the ignition button on the fascia panel. As soon as the burner is lit the button can be
released.
8. CHECKING THE HOTPLATE
Lift the lid. Fit the burner crowns and caps ensuring that they are correctly seated. Fit the pan supports.
Check each of the hotplate burners in turn by turning the hotplate tap to it's full on position and pressing the
ignition button. As soon as the burners are lit the button can be released.
9. CHECKING LID CUT-OFF DEVICE
1. Lift the lid.
2. Turn one hotplate burner tap to its full on position and push the ignition button.
3. Close lid. There should now be no gas supply to the hotplate and the burner will go out.
4. Turn off the hotplate tap and lift the lid. The gas supply should now be restored to the hotplate when the
tap is turned on.
10. CHECKING THE MAIN OVEN
1. Turn the oven thermostat knob to Mk 9 and press the ignition button. As soon as the burner is alight the
button can be released..
2. There should now be a low gas rate to the burner, which is the F.S.D. by pass rate.
3. When the F.S.D. phial has heated up it opens the F.S.D. valve which allows the main gas supply to the
oven burner.
4. Set the oven control to Mk 2, close the oven door and check that after about 10 minutes the flame size
has reduced.
5. Turn off the control and check that the oven flames go out.
GENERAL NOTE
Instruct the user on how to use the appliance and its ignition system. Refer the user to the wording in the
inside cover which gives advice on the safe operation of the appliance.
Z C G 6 2 0 0