Zanussi ZCM 611 Range User Manual


 
19
Important Safety Requirements
This appliance must be installed in accordance with the
Gas Safety (Installation and Use) Regulations (current
addition) and the I.E.E. Wiring Regulations. Detailed
recommendations are contained in the following British
Standard Codes of Practice - B.S. 6172, B.S. 5440: Part
2 and B.S. 6891: Current Editions.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be met.
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
3
, if it is installed in a room
of volume less 5m
3
an air vent of effective area of 110cm
2
is required; if it is installed in a room of volume between
5m
3
and 10m
3
, an air vent of effective area 50cm
2
is
required, while if the volume exceeds 11m
3
no air vent is
Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY: II 2H3+
APPLIANCE GAS SUPPLY: Natural Gas 20 mbar
Dimensions
Height 900 mm
Depth 600 mm
Width 600 mm
Oven Capacity 1.8 Cu. ft
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.057 0.190 0.038 0.095 0.028
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 202 43.5 144 29 72 21,5
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL
GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37
mbar
1/100 mm
1/100 mm
VALUE =
49.92 MJ/Kg
VALUE =
37.78 MJ/m
3
Ws -
50.7 MJ/ m
3
Instructions for the Installer
Hob
Rear left burner (semi-rapid) 2.0 kW
Front left burner (rapid) 3.0 kW
Rear right burner (semi-rapid) 2.0 kW
Front right burner (auxiliary) 1.0 kW
Oven
Convection Heating Element 2,090 W
Grill Element 1,830 W
Convection Fan 30 W
Oven light 15 W
Total rating 2,135 W
Supply voltage (50 Hz) 230-240 V
required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
Location
The cooker may be located in a kitchen, a kitchen/diner
or bedsitting room but not in a bathroom or shower room.
For information regarding the fitting of flexible supply
pipes, the highest temperature at the rear of this cooker
which may come into contact with the supply pipe is
70°C above ambient.
When the appliance has been installed there must be
enough space for the glass hotplate lid to open fully