Location
This cooker has been registered as a "Class X"
appliance according to Fire Risk Regulations.
Any adjacent cabinets or walls must not exceed the
cooker's height.
The cooker may be located in a kitchen, a kitchen/
diner or bedsitting room but not in a bathroom or
shower room.
For information regarding the fitting of flexible
supply pipes, the highest temperature at the rear of
this cooker which may come into contact with the
supply pipe is 70°C above ambient.
The minimum distance combustible material can be
fitted above the cooker in line with the edges of the
cooker is 420 mm. If it is fitted below 420 mm. a
space of 50 mm. must be allowed from the edges of
the cooker. However, it is recommended that a
clearance of 500mm is allowed.
The minimum distance combustible material can be
fitted directly above the cooker is 650 mm.
Since the appliance is supplied with adjustable
feet, it should be located as shown in the
diagrams, according to the height adjustment.
Positioning the Cooker
Caution:
Some soft or badly fitted floor coverings can be
damaged when the cooker is moved across their
surface for cleaning. It is advisable to ensure that the
floor covering in the area below the cooker is either
securely fixed so as not to ruck up when the cooker
is moved or, if preferred, removed.
Curtains must not be fitted immediately
behind the cooker or within 115 mm of the
sides of the cooker.