Technical information
DIMENSIONS HEIGHT OF CANOPY: 100mm
HEIGHT OF CHIMNEY: (UPPER SECTION) 415mm
(LOWER SECTION) 740mm
WIDTH OF CANOPY: 898mm
DEPTH OF CANOPY: 507mm
ELECTRICAL SUPPLY VOLTAGE: (~50Hz) 230V
POWER CONSUMPTION: 230W
FAN MOTOR: 150W
LAMPS: (4x20W) 80W
SUITABLE FOR -
INSTALLATION ABOVE: ELECTRIC HOB: (Maximum) 7KW
GAS HOB: (Maximum) 10KW
SLOT-IN ELECTRIC COOKER: (Maximum) 12.4KW
SLOT-IN GAS COOKER: (Maximum) 13.5KW
INSTALLATION INSTRUCTIONS
Note: CE Marking certifies that this appliance complies with the requirements laid down
in EEC directive 89:336 (Electromagnetic compatibility) and subsequent modifications
and Low Voltage directive 72/23/E.
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
This appliance is fitted with a 2 core mains
cable and must be permanently connected to
the electricity supply via a double-pole switch
having 3mm minimum contact gap on each
pole. A Switched Fuse Connection Unit to
BS.1363 Part 4, fitted with a 3 Amp fuse, is a
recommended mains supply connection
accessory to ensure compliance with the Safety
Requirements applicable to fixed wiring
instructions.
This appliance conforms to BS.800:1988 and
EEC Directive No. 78 308 regarding
suppression of radio and television interference.
DOUBLE INSULATED DO NOT EARTH
Page 10