Zephyr AHZ-M90AWX Ventilation Hood User Manual


 
NOTE! The device in this version
(with external blower) is equipped for
rear discharge of exhaust air. However,
if required, it is possible to have the
exhaust air discharged from the top.
This can be accomplished by carrying
out the steps indicated in the follow-
ing paragraphs; upon reaching step 5,
the blower plate must be rotated and
installed in the opposite direction.
The following instructions are for preparing the hood for use with an ex-
ternal or in-line blowers models CBE-1000 or PBN-1000A.
CAUTION: To reduce the risk of  re and electric shock, install this rangehood
only with remote blowers rated maximum 6.2 A.
For internal blower instructions please turn to page 10.
1. Unclip the top cover. Fig.1
2.
Remove the metal blower plate by
striking it with the aid of a slotted
screwdriver Fig.2
3. Remove the (6) screws securing the
blower plate to the blower housing
and remove blower plate. See.Fig.3
4. Install the chosen flange: rectangular
(A) or circular (B), and fix it to the blo-
wer plate with the (4 type B) screws.
Fig 4
Installation - External & In-Line Blower Preparation
- 13 -