Zephyr AHZ-M90AWX Ventilation Hood User Manual


 
Installation - Power Supply Connection
GENERAL
• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations.
POWER SUPPLY CONNECTION
For connection to the power supply refer to the following:
1. Open the  ap Fig.16
2. Remove the power supply cover by undoing
the (2) screws Fig. 17.
3. Connect the wires of the hood to those of
the power supply as described. Fig.18 :
BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground
- A double-pole switch properly rated must
be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field
Wiring Compartment using listed conduit
ttings.
- Carry out the power supplly connection in
accordance with the national electric code,
ANSI/NFPA 70-1999.
4. Insert the wires into the box, then close the
box cover, securing it using the screws that
were previously removed.
5. Close the  ap until it clicks into place.
- 19 -