Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG0HWDO
Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture
UHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUH
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters in Pkg.
ZRA-E36AS ZRC-0150 2
ZRA-E42AS ZRC-0151 3
1. Assemble mounting brackets and plastic collar onto air
diverter plate as shown in the image to the right. Secure
air diverter plate to top support frame using 4 screws.
Air diverter openings should face the louver holes of the
top duct cover. Run 6” ducting from top of hood to plastic
collar on air diverter plate and seal with aluminum duct
tape.
Note: Damper is not necessary when using hood in
recirculating mode.
 5HPRYHPHWDO¿OWHUVIURPKRRG&OLSFKDUFRDO¿OWHUVRQWR
FKDUFRDO¿OWHUEUDFNHWVXQGHUWKHKRRGERG\
 5HLQVWDOOPHWDO¿OWHUV
&KDUFRDO¿OWHUVVKRXOGEHUHSODFHGHYHU\PRQWKVEDVHG
RIIKRXURIFRRNLQJSHUGD\GRQRWZDVKFKDUFRDO¿OWHUV
Charcoal Filter Dimensions:
9in x 6 3/8in
228mm x 162mm
Installation – Ductless Recirculation