SERVICING INSTRUCTIONS (continued)
13
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric
power before opening the
access panel.
The QUALITY TIMER flashes
the SATELLITE light at the end
of the set interval to signal that
the coffee has lost freshness.
Discard the coffee in the
satellite and either brew a fresh
batch or clean the satellite for
future use.
Quality time interval begins
when the brew switch is
pressed.
When the light is flashing,
coffee will continue to be
maintained at temperature until
the satellite is removed from the
brewer.
Removing the satellite for
5 seconds will reset the timer.
QUALITY TIMER ADJUSTMENT
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
FREQUENCY: As required to adjust delivered volume
TOOLS: Phillips head screwdriver
Satellite or other container to calibrate volume
1. Press HEATER ON/OFF switch to OFF. Disconnect brewer
from electrical power.
2. Remove TOP PANEL. Operating controls are accessible
through the top panel only.
3. Adjust the QUALITY TIMER setting.
Turn CLOCKWISE to increase time;
Turn COUNTER-CLOCKWISE to decrease time.
Adjustment range is from 30 to 120 minutes.
4. Replace TOP PANEL. Turn TANK HEATER switch ON.
Reconnect brewer to electrical power.
Procedure is complete
661 74415 9311 Single Satellite Brewer