Simplex or Full Duplex Mode Operation
ESX-1320/ESX-1380 Installation Guide 2-3
To set a port for full duplex operation using MIB Navigator, proceed as
follows:
1. Access Local Management as described in the ESX-1320/ESX-1380
Local Management Guide.
2. Select MIB Navigator via the Local Management Main Menu screen.
The
MIBNav -> prompt appears.
3. Enter the following commands (shown in bold type) at the
MIBNav -> prompt as shown below:
MIBNav -> ctron
MIBNav -> cd 4/3/3/2/1/1
MIBNav -> set 5[x] y
where x equals the port number (1 through 12)
where
y can equal either 2 for simplex mode or 3 for
full duplex mode. For example:
set 5[3] 3 would set
port 3 for full duplex operation.
For more information concerning MIB Navigator, refer to the
ESX-1320/ESX-1380 Local Management Guide.