3-16
Catalyst 2948G-L3 and Catalyst 4908G-L3 Software Feature and Configuration Guide
78-10408-01, Cisco IOS Release 12.0(7)W5(15d)
Chapter 3 Initial Switch Router Configurations
Updating the System Image
Verifying checksum... OK (0x799F)
3173128 bytes copied in 177.668 secs (17927 bytes/sec)
Router# dir bootflash:
Directory of bootflash:/
1 -rw- 3173128 <no date> cat2948g-in-mz.120-7.W5.14.45
16777216 bytes total (13604024 bytes free)
Router# copy tftp: bootflash:
Address or name of remote host [172.10.00.00]?
Source filename [domino/cat2948g-in-mz.120-7.W5.14.45]? domino/cat2948g-in-mz.12
0-7.W5.14.46
Destination filename [cat2948g-in-mz.120-7.W5.14.46]?
Accessing tftp://172.10.00.00/domino/cat2948g-in-mz.120-7.W5.14.46...
Erase bootflash: before copying? [confirm] no
Loading domino/cat2948g-in-mz.120-7.W5.14.46 from 172.10.00.00 (via FastEthernet
1): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!
!
[OK - 3173364/6345728 bytes]
Verifying checksum... OK (0x755F)
3173364 bytes copied in 210.364 secs (15111 bytes/sec)
Router# dir bootflash:
Directory of bootflash:/
1 -rw- 3173128 <no date> cat2948g-in-mz.120-7.W5.14.45
2 -rw- 3173364 <no date> cat2948g-in-mz.120-7.W5.14.46
16777216 bytes total (10430596 bytes free)
Note Make sure that the file size of the image file you copied to boot flash memory matches the
image file size on the server.
Reloading the Switch Router
When the configuration register is set for manual booting, issuing the reload command causes the
system to enter ROM monitor mode, where you enter the boot command and the name of the system
image to use. To perform this procedure, you must be connected to the console port, which provides
access to the switch router when in ROM monitor mode. For automatic booting, you can issue the
reload command from an Ethernet connection to the route processor.
Note This procedure assumes that you need to change the boot field in the configuration register
from its default value so that the system reverts to ROM monitor mode when you issue the
reload command.