sbe1 speed=100 fullDuplex=1 flowControl=0
Note The command spineip changes the IP address for image1 and image2,
SFS 7012 Component LEDs
Chassis Status LED
The chassis status LED is Green when the system is functioning normally.
The chassis status LED is Amber when one of the following conditions exists:
The system ambient temperature exceeds 52 C but remains less than 60 C.
Any Fan Alarm is amber.
Any power supply AC OK LED is off.
Any power supply DC OK LED is off
Any spine module Attention LED is on, or it has been determined that a spine is not functioning
(even if it is unable to light the LED).
Any leaf module Attention LED is on, or it has been determined that a leaf is not functioning (even
if it is unable to light the LED).
The chassis status LED is Red when the system can no longer function properly and indicates one of the
following conditions:
The system ambient temperature exceeded 60 degrees C.
No functional fan trays are present.
No functional spines are present.
No functional leaves are present.
The chassis status LED is off when:
There are no functional power supplies present.
There are no management cards in the system
AC power has been removed from the system.
Subnet Manager Agent (SMA) LED
There is a single SMA LED associated with the system. This LED is Blue if any external InfiniBand
links have been established. If no external IB links have been established, the LED if off.
RJ45 LEDs
The SFS 7012 RJ45 connector has two LEDs, Act and 100. The 100 LED is Green when a 100Mbps
link is connected. The Act LED is Green when an Ethernet link has been established, and blinking when
the link is active.
Fan LEDs
Fan LEDs indicate the following status(es):
Green indicates that the fan is functioning properly.