Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02
Connecting a Cable to the 24-Port FXS Analog Interface Module Port
Connecting a Cable to the 24-Port FXS Analog Interface Module
Port
Caution If the symbol of suitability with an overlaid cross (cross-hockey sticks symbol) appears above a port,
you must not connect the port to a public network that follows the European Union standards.
Connecting the port to this type of public network can cause severe injury or damage your switch.
Use a standard RJ-21 Category 5 telco connector and cable to connect to the RJ-21 connector. Two types
of RJ-21 connectors are shown in Figure 5 and Figure 6. A pinout for the module’s RJ-21 connector is
provided in Table 6.
Figure 5 RJ-21 Telco Interface 90-Degree Cable Connector
Figure 6 RJ-21 Telco Interface 180-Degree Cable Connector
11485
Table 6 RJ-21 Connector Pinout
Port
Number
Connector Pin
Number Signal
Port
Number
Connector Pin
Number Signal
11
26
Ring
Tip
13 13
38
Ring
Tip
22
27
Ring
Tip
14 14
39
Ring
Tip
33
28
Ring
Tip
15 15
40
Ring
Tip
44
29
Ring
Tip
16 16
41
Ring
Tip
11486