Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02
Front Panel Description
For detailed information on power management, refer to the Catalyst 6500 Series Switch Software
Configuration Guide.
Environmental Monitoring
Environmental monitoring of chassis components provides early warning indications of possible
component failure to ensure safe and reliable system operation and avoid network interruptions.
For detailed information on environmental monitoring, refer to the Catalyst 6500 Series Switch Software
Configuration Guide.
Front Panel Description
The 24-port FXS analog interface module front panel features are shown in Figure 1 and are described
in the following sections.
Figure 1 24-Port FXS Analog Interface Module
Status LED
When the 24-port FXS analog interface module is powered up, it initializes various hardware
components and communicates with the supervisor engine. The Status LED on the module is described
in Table 3.
Note For detailed information on the supervisor engine LEDs, refer to the Catalyst 6500 Series Switch Module
Installation Guide.
33431
WS-X6624-FXS
24 PORT FXS ANALOG STATION
1
4
7
10
13
16
19
22
2
5
8
11
14
17
20
23
3
6
9
12
15
18
21
24
24-1
STATUS
Table 3 24-Port FXS Analog Interface Module Status LED
Color Description
Off The module is waiting for the supervisor engine to grant
power
The module is not receiving power. Module was powered
down due to lack of power (module listed as power-deny in
the show module status field)
Red The line card processor powered up, but is not running
The line card processor detected a fatal error during its
diagnostics
Overtemperature condition (major threshold exceeded)