Installation (for qualified installers only) 11
© Travis Industries 4080214 100-01182_003
Fireplace Placement Requirements
• The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the
framing members. No material (insulation, framing, etc.) may be placed into this area.
• Fireplace must be installed on a level surface capable of supporting the fireplace and vent
• Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or
carpet)
• This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Clearances
• When installed, walls in front of the fireplace must be a minimum 1" to the side of the fireplace.
• Due to the high temperature, the heater should be located out of traffic and away from furniture
and draperies.
• Fireplace must be placed so the vents below and above the glass do not become blocked.
Raised Fireplaces
• The fireplace (and hearth, if desired) may be placed on a platform designed to support the
fireplace (225 Lbs.) and vent.
Platform
Min. 49”
Fireplace
Enclosure
Height
Optional Raised Hearth
(see “Hearth Requirements” for details)