Technical Data
3:1 Ratio President Pumps,
Models 220561, 220564, 237222, 237223, 239855, 239854, 240618, and 240619
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A 0.7 MPa, 7 bar (100 psi) air pressure
B 0.49 MPa, 4.9 bar (70 psi) air pressure
C 0.28 MPa, 2.8 bar (40 psi) air pressure
Performance Charts
0
100
200
300
400
500
02468101214
Fluid Outlet Pressure
12 25 37
psi
MPa, bar
cycles per minute
gpm
liters/minute
815233038
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
FLUID PRESSURE
1.4, 14
0.7, 7
A
B
C
49
46
0
10
20
30
40
50
02468101214
Air Consumption
scfm
m#/min
cycles per minute
gpm
liters/minute
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
AIR CONSUMPTION
0.84
0.56
A
B
C
1.12
0.28
61
54
73 86
1.40
2.1, 21
2.8, 28
3.5, 35
12 25 37
815233038
49
46
61
54
73 86