Installation (All Pumps)
Mount the Pump
This pump can be mounted on a floor stand, cart, wall
bracket, or drum. The floor stand shown in Figs. 4 and
5 is Part. No. 220581.
Instructions for mounting the pump are supplied with
the mounting accessory.
Plumbing
Most displacement pumps have a 1–1/2 in. npt(f) fluid
inlet and a 1 in. npt(f) fluid outlet. Models 240606,
240607, 240608, 240609, 240610, 240611, 240612,
and 240613, have a 1–1/2 in. bsp(f) fluid inlet and a
1–1/4 in. bsp(f) fluid outlet.
Use a minimum 25 mm (1 in.) diameter pipe or hose
between the pump outlet and any supply line accesso-
ries. Use a minimum 38 mm (1–1/2 in.) diameter pipe
or hose between the mix tanks and pump inlet.
When using a stainless steel pump, use stainless steel
plumbing to maintain a corrosion-resistant system.
Pumps With Tri-Clamp Adapters
Displacement Pumps 240606, 240608, 240610, and
240612 include tri-clamp adapters which allow sanitary
pipe to be connected to the pump inlet and outlet.
Refer to Fig. 2.
Install a 1–1/2 in. tri-clamp gasket (GG, not supplied)
in the groove of the tri-clamp adapter (LL). Mate the
tri-clamp adapter with the sanitary pipe and secure
with two clamps (HH), bolts (JJ), and nuts (KK) (not
supplied). Install the bolts in opposite directions.
8689A
Fig. 2
GG
LL
HH
JJ
KK