A SERVICE OF

logo

44 308017
Technical Data (Quiet Bulldog Pumps)
FLUID FLOW
(TEST FLUID: 1900 CENTIPOISE OIL)
0
1000
2000
3000
4000
5000
0.0 0.5 1.0 1.5 2.0 2.5
gpm
60
1.9
1.68
20
3.8 7.6
60
30
0.84
A
B
C
A
B
C
5.7
40 80
9.5
90
2.52
120
0
1000
2000
3000
4000
5000
0.0 0.5 1.0 1.5 2.0 2.5
1.9
20
3.8 7.6
60
A
B
C
A
B
C
5.7
40 80
9.5
70
7
140
14
210
21
280
28
350
35
liters/min
To find Fluid Outlet Pressure (MPa/bar/psi) at a specific fluid flow
(lpm/gpm) and operating air pressure (MPa/bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (MPa/bar/psi):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (gray). Follow right to scale to read air consumption.
cycles/min
scfm
m#/min
FLUID FLOW
(TEST FLUID: 100,000 CENTIPOISE SEALANT)
KEY: Fluid Outlet Pressure - Black Curves
Air Consumption - Gray Curves
A 0.6 MPa, 6.2 bar (90 psi) Air Pressure
B 0.49 MPa, 4.9 bar (70 psi) Air Pressure
C 0.28 MPa, 2.8 bar (40 psi) Air Pressure
psi
bar
MPa
3.36
60
1.68
30
0.84
90
2.52
120
scfm
m#/min
3.36
cycles/min
70
7
140
14
210
21
280
28
350
35
psi
bar
MPa
gpm
liters/min