A SERVICE OF

logo

308017 7
Installation
Fluid Line Accessories
Install the following accessories in the positions shown
in Fig. 1, using adapters as necessary:
D Install a fluid drain valve (L) in a tee near the
pump fluid outlet. The drain valve is required in your
system to relieve fluid pressure in the displacement
pump, hose and gun/valve (see the WARNING on
page 6). Install with the drain valve pointing down,
but so the handle points up when the valve is open.
D A fluid regulator (M) controls fluid pressure to the
gun/valve, and dampens pressure surges.
D A gun or dispense valve (N) dispenses the fluid.
The gun shown in Fig. 1 is a high pressure dispens-
ing gun for highly viscous fluids.
D A gun/valve swivel (P) allows freer gun/valve
movement.
Air and Fluid Hoses
Be sure all air hoses (S) and fluid hoses (R) are prop-
erly sized and pressure-rated for your system. Use
only electrically conductive hoses. Fluid hoses must
have spring guards on both ends.
05683
Fig. 1
KEY
A Pump
B 19 Liter (5 Gallon) Air-Powered Ram
C Wiper Plate
D Air Manifold
E Pump Runaway Valve (location shown)
F Air Line Lubricator (location shown)
G Pump Bleed-Type Air Valve
(required, for pump)
H Pump Air Regulator
J Air Line Filter
K Bleed-Type Air Valve (for accessories)
L Fluid Drain Valve (required)
M Fluid Pressure Regulator
N Airless Spray Gun or Dispensing Valve
P Gun/Valve Swivel
Q Ram Air Pressure Relief Valve
R Electrically Conductive Fluid Supply Hose
S Electrically Conductive Air Supply Hose
T Ram Air Regulator
U Ram Director Valve
V Red-Handled Main Air Bleed Valve
W Air LIne Drain Valve
Y Ground Wire (required, see page 8 for
installation instructions)
A
B
D
E
F
G
JK
Y
R
T
L
N
P
S
M
C
W
H
S
V
QU