System Adjustment
313384B 15
Material Flow Adjustment
For a lighter spray pattern, decrease material pres-
sure at sprayer.
For a heavier spray pattern, increase material pres-
sure at sprayer.
Air Flow Adjustment
Trigger gun.
To decrease air flow, close air valve (23) clockwise.
To increase air flow, open air valve (23) coun-
ter-clockwise.
Preventing Material Surge at
Gun Trigger
Pressure will build up in system when not triggering gun.
To prevent material surge at beginning of spray pattern:
Point gun away from surface to be sprayed when
trigger is first pulled.
Hold gun away from surface and gradually bring gun
to surface.
Trigger gun as little as possible.
For Continuous Spraying
Engage trigger lock (D) to hold trigger open and
reduce fatigue.
ti4339a
B
TI
23
NOTE: Keep a small amount of air flowing through
air line and gun tip to prevent material from backing
up needle.
ti4006a
D