P/N 480-0005-00-15 7-5
Chapter 7: System Alarms
Critical Configuration Mismatch A mismatch has occurred for the card in the slot and the
actual configuration. For example, this alarm would
occur if you insert a DSP card in a slot that has an earlier
configuration for a T1 card.
Critical Operational Code Missing Normal application code for T1/E1, System Controller,
CPU, or DSP card is damaged.
Critical Configuration Data Missing Configuration via CLI is missing. Check the configura-
tion data and add the necessary information.
Critical Power Degrade One power supply is not working correctly.
Critical IVR Configuration Missing Appears if an attempt to make an IVR call has been
made when a valid IP address is not configured.
If an IVR call has been passed through accidently, with-
out a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
Critical RADIUS Configuration Missing Appears when a RADIUS request is made and one or
more required configuration parameters are missing.
This alarm is cleared when the required RADIUS
parameters are configured via CLI.
Critical RADIUS Server Not Responding Appears when none of the configured RADIUS servers
respond.
This alarm is cleared when any of the RADIUS servers
responds or the RADIUS server is disabled via CLI.
Critical IVR Configuration Missing Appears if an attempt to make an IVR call has been
made while neither of the two IVR Prompt Server IP
addresses are set in the database; an IVR enabled trunk
group receives a call for which the IVR Prompt Server
IP is not configured.
If an IVR call has been passed through accidentally,
without a real intention to use IVR for subsequent calls,
while both of the servers were disabled. In order to clear
the alarm, a user will have to change one of the IP
addresses to some value, and then disable it again.
Major Major Software Error A software error has occurred that affects system signal-
ing, interfaces, or other major operation.
Severity
(appears as
part of severity
field)
Alarm Description
(text appears in desc field)
Definition