Figure 5 Installing t he Brocade 8 Gb SAN Switch into an interconnect bay
5. Press the installation handle into the latch to lock the Brocade 8Gb SAN Switch in place.
CAUTION:
All panels and doors should be in p lace and securely fastened while the unit is in operation, for proper
cooling and for E MI emissions control.
OA power verification
As defined earlier, the HP BladeSystem Onboard Administrator (OA) is the enclosure management
processor that manages the devices contained within the enclosure. The OA provides a single point from
which to perform basic management tasks on switches or server blades installed in the enclosure.
IMPORTANT:
HP recommend s reading the appropriate
HP BladeSystem Enclosure User Guide
and the
HP BladeSystem
Onboa rd Administrator User Guide
. Reading these guides in sequence will promote an overall understanding
of your specificenclosuremodel.
Once the switch is installed in the interconnect bay, the OA verifies that the switch type matches the
mezzanine cards present on the servers. If there is no mism atch, the OA powers up the switch.
If the switch does not power up, check the enclosure and switch status with the OA web interface. Refer to
the HP BladeSystem Onboard Administrator User Guide.
Check L
EDs
See Figure 6 to locate power-on LEDs. Verify that the LEDs match the indicators described in Table 10.
22 Setup