29
Release Notes for 07.8.04 Software Fixes
32360 On an EP 48-Port 10/1000-TX RJ45 module, the
routing switch does not successfully remove some
ACL remarks and line entries from the
configuration. This occurs if you delete an ACL (for
example, no access-list 130) and then later create
an ACL with the same ACL number (for example,
access-list 130). In this case, the system
incorrectly inserts some of the remarks and entries
from the previously deleted ACL.
ACL 07.8.01
32448 On an EP 8 Port Mini-GBIC Redundant
Management module, PIM registration packets are
sent with an incorrect source IP address.
PIM Sparse 07.8.01
32462 The show debug command output does not
indicate that debug span or debug 802.1w
commands are enabled on the routing switch.
CLI 07.8.01
32735 The routing switch corrupts the Autonomous
System (AS) path if all three of the following
conditions exist:
• The routing switch is configured (using the
remove-private-as command) to remove
private AS numbers from update messages
sent to a neighboring device.
• The routing switch is configured (using the as-
set parameter in the aggregate-address
command) to aggregate AS path information
for all the routes in the aggregate.
• The first as-set segment has a private AS
number.
BGP 07.8.01
32854 On an EP 24 Port 100Base-FX module (J8178A), a
port’s Full Duplex (FDX) LED does not illuminate
even though the port has a fixed configuration of
100 full-duplex, and the port is connected to another
routing switch that also has a fixed 100 full-duplex
configuration.
MAC 07.8.01
32857 Connectivity issues may occur If MAC
authentication is enabled on an M4 Redundant
Management module.
MAC
Authorization
07.8.01
32906 The system truncates the number of days
timestamp for buffered Syslog messages. For
example, if the actual system uptime is:
382 days 23 hours 17 minutes 26 seconds
The software displays:
38 days 23 hours 17 minutes 26 seconds
Syslog 07.8.01
Bug ID Bug Description Protocol/
Feature
Version
Found
Version
Fixed