FUEL SYSTEM (DFI) 3-21
DFI Servicing Precautions
After measurement, remove the needle adapters and ap-
ply silicone sealant to the seals [A] of the c onnector [B]
for waterproofing.
Silicone Sealant (Kawasaki Bond: 56019-120) -Seals
of Connector
Always check battery condition before replacing the DFI
parts. A fully charged battery is a must for conducting
accurate tests of the DFI system.
Do not directly connect a 12 V battery to a fuel injector.
Insert a resistor (5 7 ) or a bulb (12 V, 3 3.4 W) in