APPENDIX 4 SYSTEM MODE
EO1-33029
A4.4 Printer Parameter Fine Adjustment
A4-12
A4.4 Printer Parameter
Fine Adjustment
(Cont.)
Threshold Manual Fine Adjustment (Black Mark/Feed Gap
Sensor)
With this parameter you can fine adjust the Threshold of the Black Mark
and Feed Gap Sensors. When “<3>ADJUST SET” appears, press the
[PAUSE]
key 9 times to enter the Threshold Manual Fine Adjustment
(Black Mark Sensor) menu.
To change the screen to the Threshold Manual Fine Adjustment (Feed
Gap Sensor), press the
[PAUSE]
key again.
[FEED]
key: Pressing the
[FEED]
key one time causes a –0.1V change,
up to 0.0V.
[RESTART]
key: Pressing the
[RESTART]
key one time causes a
+0.1V change, up to +4.0V.
After completing the fine adjustment, press the
[PAUSE]
key.
NOTE:
This is useful to fine adjust the
threshold when the media issue
is improper even after the
sensor threshold setting is
erformed. (See Section 6.5
Threshold Setting) If the
roblem cannot be resolved,
lease contact your nearest
TOSHIBA TEC service
representative.
7+5(6+2/'7!9
[RESTART]
[FEED]
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
Black Mark Sensor Feed Gap Sensor
7+5(6+2/'5!9
Black Mark Sensor
Feed Gap Sensor