A SERVICE OF

logo

Manual
7/24/2014
PSFEM2xxxGRxxx
Viking Technology
Revision A10
Page 14 of 43
www.vikingtechnology.com
the use of the hold-up circuit. Note that SMART attribute 174 "Unexpected Power
Loss" records the number of non-graceful power cycle events.
Table 2-4: STANDBY IMMEDIATE Timing
Power Cycle Endurance
Min
Max
Unit
STANDBY IMMEDIATE to WE completed
-
72.9
ms
Notes: From Standby Immediate command to NAND Write Protect enable.
2.3 Electrical Characteristics
2.3.1 Absolute Maximum Ratings
Values shown are stress ratings only. Functional operation outside normal
operating values is not implied. Extended exposure to absolute maximum ratings
may affect reliability.
Table 2-5: Absolute Maximum Ratings
Description
Min
Max
Unit
Maximum Voltage Range for Vin
-0.2
6
V
Maximum Temperature Range
-40
85
c
2.3.2 Supply Voltage
The operating voltage is 3.3V or 5.0v
Table 2-6: Operating Voltage
Description
Min
Max
Unit
Operating Voltage for 3.3 V or 5.0 (+/- 5%)
3.135
5.25
V
Notes: 5V not supported on VRFEM2xxxGRxxxJx PN’s