INSTALLATION AND CONNECTION
2-1 Installing the SRCP Controller
2-1 Installing the SRCP Controller
2-1-1 Installation method
Using the L-shaped brackets attached to the top and bottom of the controller, install the controller
from the front or rear position. (See Fig.1-2 Three-side view of the SRCP controller.)
2-1-2 Installation location
Install the controller in locations where the ambient temperature is between 0 to 40°C and the
humidity is between 35 to 85% without condensation.
Do not install the controller upside down or at an angle.
Install the controller in locations with sufficient space (at least 20mm away from the wall or
other object) for good ventilation and air flow.
Do not install the controller in locations where corrosive gases such as sulfuric acid or hydro-
chloric acid gas are present, or in atmosphere containing flammable gases and liquids.
Install the controller in locations with a minimal amount of dust.
Avoid installing the controller in locations subject to cutting chips, oil or water from other
machines.
Avoid installing the controller in locations where electromagnetic noise or electrostatic noise
is generated.
Avoid installing the controller in locations subject to shock or large vibration.