Acme Kitchenettes PP-32 Ventilation Hood User Manual


 
73
PP-32
KOOLMASTER PP-32 REV.01
To assign relays on timer mode, proceed
as described above and use the adjust-
ment buttons to select the "Timer"
option.
5.14.6.2 Assigning Heater Stages' Relays
Set the function to "16.Heater Settings" from the main menu using
the navigation buttons then press the right-arrow key. Note that this
menu is only available in the installer mode (see sec. 5.14.2).
Press the right-arrow key once again to select the "1.Relays" menu.
Use the navigation buttons to select the desired heater stage then
press the right-arrow key.
Use the right and left-arrow keys to
select the desired relay. When the
item is flashing, press to activate
the relay or to deactivate it.
Proceed in similar fashion to assign relay(s) for each heater stage.
5.14.6.3 Assigning Relays to Vent Doors
Relays 13-14, 15-16, 29-30 and 31-32 have specially been designed for
vent doors, air inlets or tunnel curtain. It is strongly recommend to use
these relays to open/close these devices: this prevents activating the
OPEN and CLOSE relays, by inadvertence, at the same time.
ASSIGNING VENT DOORS OPEN / CLOSE RELAYS:
Set the function to "8.Vent Doors" from the main menu using the
navigation buttons then press the right-arrow key. Note that this menu
is only available in the installer mode (see sec. 5.14.2) and if vent
doors have been enabled during the installation setup (see sec 5.14.3).
Heater 1 Relays
1 2 3 4 5 6 7 8 9 10
Stage 1a Relays:
Relay 1 On(1)
Relay 2 Timer(1)
Relay 3 Off(1)