AEG MC1761E Microwave Oven User Manual


 
27
Installation
INSTALLING THE APPLIANCE
1. Remove all packaging and check carefully for any
signs of damage.
2. This oven is designed to fit into a 360 mm high
cupboard as standard.
When fitting into a 350 mm high cupboard:-
Unscrew and remove the 4 feet from the bottom of
the oven. There are 3 tall feet and 1 short foot.
Replace the 3 tall feet with those provided in the
accessory pack. Do not replace the short foot.
3. If fitting the microwave oven above a conventional
oven (position A) then use the mylar sheet provided.
a. Cut the Mylar sheet to
fit the internal
width of the
unit.
b. Peel back the
protective
cover on the
tape and fix
to the rear of
the shelf so
that it covers
the service gap.
(See diagram).
4. Fit the appliance into the kitchen cupboard slowly,
and without force, until the front frame of the oven
seals against the front opening of the cupboard.
5. Ensure the appliance is
stable and not leaning.
Ensure that a 5 mm gap is
kept between the cupboard
door above and the top of
the frame (see diagram).
6. Fix the oven in position with the
screws provided.
The fixing points are located on
the top and bottom corners of
the oven (see diagram, item 9,
on page 4).
7. It is important to ensure that the installation of this
product conforms to the instructions in this
operation manual and the hob or conventional oven
manufacturer’s installation instructions.
5 mm
Mylar sheet
Conventional
oven
Internal width
Service gap
If fitting the microwave in position B or C:
The cupboard must be a minimum of
500 mm (E) above the worktop & must
not be installed directly above a hob.
This appliance has been tested and
approved for use near domestic gas,
electric and induction hobs only.
Sufficient space between hob and
microwave should be allowed to prevent
overheating of microwave oven,
surrounding cupboard and accessories.
Do not operate the hob without pans
when the microwave oven is operating.
Care should be taken when attending to
the microwave oven while the hob is on.
SAFE USE OF THE APPLIANCE
E
D
Position A
Position B
Position C
Position D
Conventional
oven
POSITION NICHE SIZE CHIMNEY Gap Between
W D H (min) Cupboard & Ceiling
A 560 x 550 x 360 50 50
B + C 460 x 300 x 350 15 50
460 x 300 x 360 15 50
560 x 300 x 350 15 50
560 x 300 x 360 15 50
D 460 x 500 x 350 40 50
460 x 500 x 360 40 50
560 x 500 x 350 40 50
560 x 500 x 360 40 50
Measurements in (mm)