Aga Ranges GC Cooktop User Manual


 
NOTE: AFTER SEVERAL HOURS THE HEAT
INDICATOR SHOULD BE ON OR ABOUT THE BLACK
LINE IN THE SILVER SECTION.
IT MAY BE NECESSARY TO ADJUST THE CONTROL
KNOB SLIGHTLY IN THE GREEN BAND TO ACHIEVE
THIS.
IF THE FLAME HAS EXTINGUISHED FOR WHATEVER
REASON, WAIT THREE MINUTES (MINIMUM) BEFORE
RE-LIGHTING.
7. On the first lighting or if the cooker has been cold for
a long time. moisture from the insulation may run
down the enamelled front of the cooker. This should
be wiped off to prevent staining.
8. Check the inlet gas pressure is as indicated in the data
plate as follows:
(i) Turn the gas valve control knob 2 to OFF position (see
Fig. A). Remove the inlet pressure test nipple plug 5
and fit pressure gauge. Turn gas valve control knob 2
to the mid position of green band.
(ii) Check inlet pressure correctly corresponds to the
data plate.
(iii)Check that the gas pressure is unaffected when other
gas appliances are used.
(iv)Turn gas valve control knob 2 to ignition position (see
Fig. B). Remove the pressure gauge and replace gas
nipple plug. Turn gas valve control knob 2 to the
mid-position of the green band for normal running.
NOTE FOR L.P. COOKERS ONLY
Repeat instruction 8 on completely cold cooker with the
pressure gauge fitted to the burner pressure test point 6.
Check that the burner pressure correctly corresponds to
the table on pages 2 or 3.
NOTE: IF FOR ANY REASON A GAS RATE CHECK IS
REQUIRED, TURN OFF ALL OTHER APPLIANCES
USING GAS AND USING THE GAS METER TEST DIAL
AND STOP WATCH, CHECK THAT THE MAXIMUM GAS
INPUT IS AS INDICATED ON THE DATA PLATE.
Once the correct setting has been confirmed, the heat
control will operate automatically to maintain the
cooker at full temperature.
NOTE: REMEMBER TO NOTE THE SETTING
POSITION IF TURNING OFF THE COOKER.
Hand these and the Operating Instructions to the User for
retention and instruct in the safe operation of the
appliance.
Advise the User of the precautions necessary to prevent
damage to the Domestic Hot Water System and to be
building in the event of the Domestic Hot Water System
remaining inoperative during frost conditions.
Finally advise the User that, for continued efficient and
safe operation of the appliance it is important the
adequate servicing is carried out at regular intervals
recommended by the Aga Distributor or local Gas Region.
7