Alto-Shaam 1000-BQ2/192 Food Warmer User Manual


 
1000-BQ2 (Rev. 1) seRies opeRation & caRe manual7
1. An identification tag is permanently mounted
on the cabinet.
2. Plug cabinet into a properly grounded
receptacle ONLY, positioning the unit so the
power supply cord is easily accessible in case
of an emergency.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit, must be
installed by a licensed electrician in accordance
with applicable, local electrical codes.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL CONNECTION
INSTALLATION
Wire diagrams are located inside the top of the unit.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
NOTE: Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
ELECTRICAL 1000-BQ2/128
voltage phase cycle/hz amps kW cord & plug included
120 1 60 17.5 2.1 NeMa 5-30p
30A- 125V
plug
208 1 60 7.7 1.6 nema 6-15p
240 1 60 8.9 2.1 15A - 250V
plug
230 1 50/60 8.4 2.0 cee 7/7
plug Rated 250v
ch2-16p
plug Rated 250v
BS 1363 (u.k. oNly)
plug Rated 250v
ELECTRICAL 1000-BQ2/96
voltage phase cycle/hz amps kW cord & plug
120 1 60 12.5 1.5 nema 5-15p
15A- 125V
plug
208 1 60 5.9 1.2 nema 6-15p
240 1 60 6.8 1.6 15A - 250V
plug
230 1 50/60 6.5 1.5 cee 7/7
plug Rated 250v
ch2-16p
plug Rated 250v
BS 1363 (u.k. oNly)
plug Rated 250v
ELECTRICAL 1000-BQ2/192
voltage phase cycle/hz amps kW cord & plug included
120 1 60 24.0 2.9 NeMa 5-20p
power switch in low position 16.0 1.9 20A- 125V plug
NeMa 5-30p
power switch in high position 25.0 Max 3.0 30A - 125V plug
208 1 60 11.8 2.5 nema 6-15p
240 1 60 13.6 3.3 15A - 250V
plug
230 1 50/60 13.0 3.0 cee 7/7
plug Rated 250v
ch2-16p
plug Rated 250v
BS 1363 (u.k. oNly)
plug Rated 250v