pg. 12 TH/III InsTallaTIon/operaTIon/servIce manual
ELECTRICAL CONNECTION
INSTALLATION
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “OFF” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord and
plug, an all-pole country approved disconnection
device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal which is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
NOTE: CE approved appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.