CombiTouch ERROR CODES
Error
Code
Error call out in Display Description of Error Possible reason
E57
No rinse water During rinse no water fl ow
is detected through solenoid
valve
Water supply is shut off.
Low water pressure.
Check wiring to all components mentioned below.
Flow switch is dirty or defective.
Dual water solenoid valve obstructed or faulty (Y3.)
Relay board, high voltage, defective.
E93
Communication Error,
FROM Display Board
Communication error
between display board and
low voltage
relay board
— Check ribbon cable connections mentioned below.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94
Communication Error,
TO Display Board
Communication error
between display board and
low voltage
relay board
— Check ribbon cable connections mentioned below.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E98
RB is in Cesius and DB is in
Fahrenheit
Confl ict of unit confi guration
in the setup menu
Relay board and Data board do not match, use
setup menu to change format.
E99
RB is in Fahrenheit and DB
is in Cesius
Confl ict of unit confi guration
in the setup menu
Relay board and Data board do not match, use
setup menu to change format.