Electric Fryer Operation & Care Manual • 9
INSTALLATION
An electrical wiring diagram is located in the front
access door of the fryer. The fryer must be installed by a
qualiedelectrician.Thisappliancemustbebranchcircuit
protected with proper ampacities, in accordance with
the wiring diagram located in the fryer. The fryer must
be properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnecttheunitmustbeincorporatedintothexed
wiring in accordance with wiring codes.
Wiresizeforthemainincomingpowertotheunitmust
matchtheminimumsizelistedinthespecications
applicabletothespecicfryer.Forsupplyconnections,
locate the wire size posted on the label located on the
electrical control box cover, behind the service panel or
elsewhere listed in this manual.
Before operating the fryer, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufcientprotectionagainstpotentialdifference.The
terminal is marked with the following symbol.
ELECTRICAL - ASF-60E
voltage phase cycle/hz amps kW awg
208-220 (agcy) 3 60 47.0 17.9 aWg 6
at208 3 60 45.0 16.2 aWg 6
at220 3 60 47.6 18.2 aWg 6
240
(agcy) 3 60 43.0 17.9 aWg 6
380-415
at 380 3 50 20.4 15.4 aWg 10
at415 3 50 25.4 18.3 aWg 10
440-480
(agcy) 3 60 21.8 18.1 aWg 10
at440 3 60 20.4 15.5 aWg 10
at480 3 60 22.2 18.5 aWg 10
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
ELECTRICAL REQUIREMENTS
ELECTRICAL - ASF-75E
voltage phase cycle/hz amps kW awg
208-220(agcy) 3 60 68.2 26.0 AWG2
at208 3 60 66.6 24.0 AWG2
at220 3 60 70.8 27.0 AWG2
240
(agcy) 3 60 66.8 27.8 aWg 2
380-415
(agcy) 3 50 38.1 27.5 aWg 6
at 380 3 50 35.2 23.2 aWg 6
at415 3 50 38.2 27.5 AWG6
440-480
(agcy) 3 60 31.3 26.0 aWg 8
at440 3 60 30.7 23.5 AWG8
at480 3 60 33.4 27.9 AWG8
DANGER
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
productanoilresistantcordlikeH05RNorH07RN
or equivalent must be used.