Amana HRV-150D Ventilation Hood User Manual


 
2
TABLE OF CONTENTS
TECHNICAL DATA
HRV(D) Series .................................................................................................. 3
HRV Series ...................................................................................................... 5
HRV-300D.................................................................................................... ...7
OPERATION............................................................................................................11
Modes Of Operation ........................................................................................11
Optional Remote Controls................................................................................ 12
Digital Multi-Function Controls w/recirculation.....................................................12
Digital Multi-Function Controls .........................................................................13
INSTALLATION........................................................................................................14
Mounting the Unit .......................................................................................... 14
Location & Ducting.......................................................................................... 15
Examples ....................................................................................................... 18
Air Flow Balancing ......................................................................................... 22
MAINTENANCE ..................................................................................................... 24
TROUBLESHOOTING............................................................................................... 25
ELECTRICAL CONNECTIONS ................................................................................. 26
Sizing (Example) for maximum airflow normally required.
HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per
hour. To calculate, simply take the square footage of the house (including basement) and multi-
ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.
Example: SQFT of House 1100
Basement 1100
Total SQFT 2200
Height of ceiling x 8
Cubic volume 17600
/ 60
Maximum airflow required (CFM) 293
x 0.35
103
* Always consult your local code for sizing requirements in your area.
Room classification Number of rooms CFM (L/s) CFM Required
Master bedroom x 20 cfm (10 l/s) =
Basement yes or no =
Bedrooms x 10 cfm (5 l/s) =
Living room x 10 cfm (5 l/s) =
Others x 10 cfm (5 l/s) =
Kitchen x 10 cfm (5 l/s) =
Bathroom x 10 cfm (5 l/s) =
Laundry room x 10 cfm (5 l/s) =
Utility room
x 10 cfm (5 l/s) =
Total Ventilation Requirements
(add last column )
=
if yes add 20 cfm / 10 l/s
if no = 0
1 cfm = 0.47189 l/s
1 l/s = 3.6 m
3
/hr
Alternate Method
***Illustrations &
images in this
manual may not be
exactly like unit
purchase, these
illustrations &
images are for
examples only.***