Amana MWT4461WW Microwave Oven User Manual


 
3
Materials Needed (Not Supplied)
Phillips screwdriver
Pencil
Ruler or tape measure and straight edge
Protective gloves
Carpenter square (optional)
Tin snips (in some applications)
Electric drill with 1/8 inch, 3/16 inch and 5/8 inch drill
bits
Hammer
Stud finder (optional)
Filler blocks, if needed for top cabinet spacing
Saw (jig or keyhole)
Charcoal filter kit (for inside recirculating installation)
Filler panel kit (if space between cabinets is greater
than 30 inches)
* If rectangular-to-round transition adaptor is used, bottom
corners of damper will have to be cut to fit, using tin
snips, in order to allow free movement of damper.
Materials Needed (Supplied)
Installation hardware is contained in packet shipped with
microwave oven. Verify all parts listed below are included
in packet.
Hardware Quantity
4 inch x 2 inch Wood Screws 2
3/16 inch Toggle Bolts (and spring loaded nuts) 4
1/4 inch Screws 3
Washers 3
Nylon Grommet (for metal cabinets) 2
28 inch Pieces of Foam Tape 2
Rectangular Washer 1
Top Cabinet Template* 1
Separately Packed Grease Filter* 2
* Not Shown
Hood Exhaust Duct
Outside ventilation requires hood exhaust duct. Use only
metal duct. Read the following carefully.
Exhaust Connection: Hood exhaust has been designed
to mate with standard 3 1/4 inch x 10 inch rectangular duct.
If round duct is required, rectangular-to-round transition
adaptor must be used. Do not use less than 6 inch
diameter duct.
Rear Exhaust: If rear or horizontal exhaust is to be used,
care should be taken to align exhaust with space between
studs.
Maximum Duct Length: Total duct length of 3 1/4 inch x
10 inch rectangular or 6 inch diameter round duct should
not exceed 140 equivalent feet for satisfactory air
movement.
Elbows, Transitions, Wall and Roof Caps, Etc.
Elbows, transitions, wall and roof caps, etc., create
additional resistance to airflow and are equivalent to a
section of straight duct. When calculating total duct length,
add equivalent lengths of all transitions and adaptors, plus
length of all straight duct sections. Chart below shows
approximate feet of equivalent length of some typical
ducts.
Duct
Equivalent Length
Rectangular-to-Round Transition
Adaptor
5 FT.
Wall Cap 40 FT
90° Elbow 10 FT.
45° Elbow 5 FT.
90° Elbow 25 FT.
45° Elbow 5 FT.
Roof Cap 24 FT.
Accessories Available for Purchase from
Dealer
Charcoal filter kit: Charcoal filter kit is needed for
recirculating exhaust installation.
Filler panel kit: If space between cabinets is greater
than 30 inches, filler panel kit may be used to fill in gap
between microwave oven and cabinets.
Washers
Rectangular Washer
4x2 inch Wood
Screws
3/16 inch Toggle
Bolts
28 inch Pieces of
Foam Tape
1/4 inch screws