Anetsberger Brothers MX-14-2E Fryer User Manual


 
5
Figure 1. Fryer Model MX-14E Wiring Diagram
FRYER ELECTRICAL SPECIFICATIONS
Please make sure that your desired fryer location has electrical
supply factors that are suitable for this product:
120 Volts, 60 Hz, (Refer to Table 1 for amperage requirements), 1-phase, three-wire connection, including
an electrical ground,
via a dedicated circuit breaker. A model-specific electrical circuit diagram is
mounted inside the front door of each fryer.
!
Install a dedicated, three-prong, outlet/ receptacle
within 5 feet of the desired fryer location to allow
the fryer’s power cable to be connected. Ensure
that the green (ground) wire of the fryer’s power
cable is attached to the fryer’s structure, providing
an electrical ground in accordance with applicable
local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70
(latest edition) or the Canadian Electrical Code,
CSA C22.1 (latest edition) and CSA C22.2 (latest
edition).
Table 1. Fryer Amperage
Requirements
Model Amperage
MX-14E
MX-14-2E
MX-7E
MX-14AA
MX-14-2AA
MX-7A
2 A.
4 A.
2 A.
7 A.
9 A.
5 A.
WARNING
Electrical Grounding Instructions
(See inside of door for wiring diagram.)
This appliance is equipped with a three-
prong (grounding) plug for your protec-
tion against shock hazard, and should
be plugged directly into a properly
grounded, three-prong receptacle. DO
NOT cut or remove the grounding prong
from this plug.
Figure 1 is the basic wiring diagram of an
MX-series fryer showing a typical circuit.
Some fryers may have other options that do
not appear in this basic wiring diagram. A
model-specific wiring diagram included with
each fryer shows all the actual parts and
their associated wiring connections. In
addition, fryers equipped with a built-in filter
system (Filtronic II or Filter Mate) and/or
built-in computer controls (Fri-tronic) have
a supplementary manual included for each
option.