22
STEP ACTION DISPLAY COMMENTS
13 Repeat steps 5-12 when
programming stages 2, 3, 4 and
5 for Electric and Gas appliance
types.
Repeat steps 5-10 when
programming stages 2, 3, 4 and
5 for an ALF appliance type.
The time and temperature of each
stage has to be less than the
preceding stage.
14 Press ENTER. PROGRAM PREALARM
00:00
This command allows you to
specify the number of minutes
before the end of the cooking time
(for each stage) until the alarm
sound The prealarm value
displayed may be a previously
programmed value.
15 Press TOGGLE/CLEAR and
input the prealarm minutes.
PROGRAM PREALARM
XX:XX
XX:XX refers to the prealarm
minutes you input.
16 Press ENTER. PROGRAM FILTER
0
This command allows you to
specify the number of fry cycles
you want to complete for this
program before a message is
displayed reminding you to filter
the shortening (filter lockout). The
filter value displayed may be a
previously programmed value.
17 Press TOGGLE/CLEAR and
input the number of fry cycles
you want to complete before
enabling filter lockout.
PROGRAM FILTER
X
X refers to the number of program
cycles you want to complete before
filtering the shortening.
18 Press ENTER. PROGRAM PRODUCT #
19 If you wish to input more
programs, proceed by pressing
the next program number and
follow steps 5 through 18 or
press PROG to exit the
programming mode.