7
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the abs ence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1–
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codesor,in theabsence oflocal codes,withthe
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gassupply line. Do not bendor damagethe
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator pr ovided. The regulator shall be
properlyinstalledinordertobeaccessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determinedbasedonthe sizeofyourgassupply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduring anypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholes inthe wallandfloor,back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshallbeinstalledinanaccessible
locationin thegas
lineexternal tothe appliance
forthepurposeofturning onorshuttingoff gas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used withthe appliance;in each caseit
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectotherventedappliances;in
each caseit shallbe installed inconfor mity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural
gas. For use with propane lp gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureis alsoincludedwitheachsetoflpgas
nozzles.
GASPRESSURE
Themaximuminletgas supplypressureincoming
to the gas appliance pressure regulator is 20’’
water
column(5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
theappliance(thisoperatingpressureis11”w.c.
(2.75kPa)forLPGasand4”w.c.(1.00kPa)for
NaturalGas.