Best UP271 Microwave Oven User Manual


 
- 9 -
HORIZONTAL DISCHARGE (DUCTED INSTALLATION ONLY)
The UP27I Series range hoods are factory set to exhaust vertically. If the
horizontal discharge is chosen, remove the metal shut-off plate from the
back of the hood, by removing its 3 screws. Set aside the screws. Discard
both left and right flow deviators assembled to the metal shut-off plate.
Press the metal shut-off plate on a flat surface to completely flatten bent
flange, and install on top of hood using 3 screws previously removed plus
another no. 8 x 3/8” screw (from parts bag).
Fold down the foldable flange of the chosen adapter/damper. This flange
must be at 90° from the remaining flanges. See picture beside.
HD0203
HD0119
8. PREPARE THE HOOD (CONT’D)
8.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER) (CONTD)
V
ERTICAL DISCHARGE (CONTD)
Using 4 no. 8 x 3/8” screws provided with hood, secure the chosen
adapter/damper to the top of the hood. Remove tape from damper flap.
Seal the adapter/damper to the hood using duct tape.
HD0201
HD0202
HO0112