Blanco BCGC74 - BCGC52 Cooktop User Manual


 
5) LOCATION AND VENTILATION
Ventilation must be in accordance with
AS5601/AG 601 – Gas Installations.
In general, the appliance should have adequate ventilation for
complete combustion of gas, proper flueing and to maintain
temperature of immediate surroundings within safe limits.
The wall and bench surfaces must be capable of sustaining
temperatures of 75°C.
All laminates, fixing adhesive and surfacing materials should
be certified suitable for this temperature.
6) GAS CONNECTION
This gas connection is male 1/2” BSP and is situated at the
rear of the appliance, 415 mm from the right hand side and
55 mm from the rear of the cooktop.
A. The hotplate can be connected with rigid pipe as specified
in AS5601 table 3.1.
B. If installing with a hose assembly, install with a hose
assembly that complies with AS/NZS 1869 (AGA
Approved), 10mm ID, class B or D, no more than 1.2m long
and in accordance with AS5601. Ensure that the hose does
not contact the hot surfaces of the hotplate, oven,
dishwasher or any other appliance that may be installed
underneath or next to the hotplate. The hose should not be
subjected to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length with the
cooktop in the installed position.
Unions compatible with the hose fittings must be used and
all connections tested for gas leaks.
The gas supply connection for the hose assembly must be
accessible.
Natural Gas
Natural Gas installations require the connection of a gas
regulator at the appliance. This regulator is supplied with
the appliance on purchase.
Assemble the regulator (noting the gas flow direction) and
transition pieces (supplied with the appliance), in
accordance with figure 10.
The transition piece on the supply side of the regulator
must be provided by the installer.
The appliance is factory set for Natural Gas. The test point
pressure should be adjusted to 1.00 kPa with the wok
burner operating at maximum.
Liquified Petroleum Gas
In a Universal LPG installation the gas regulation is made
at the gas cylinder and regulation at the appliance is not
required. The supply pressure should be 2.75 kPa. To
connect supply to the appliance use transition pieces as
shown in figure 11. These pieces are supplied with the
appliance on purchase.
WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY THE
INSTALLER.
FAULTY INSTALLATION WILL NOT BE COVERED
UNDER WARRANTY.
7
INSTALLATION
FIG. 10
FIG. 11