SUGGESTED REMEDY
Check power supply cord
Check / reset circuit breaker
Turn on and set for desired
temperature. See page 15
Allow to cool (1012, 1040 or
1072), or allow to cool and
reset hi-limit (1086, 1088)
Examine wiring & connectors,
controller, power board and
heating element
Repair/replace as needed
Adjust controller. See page 16
Use one (1) genuine Bloomfield
filter per brew
Thoroughly clean brew chamber
Check/reinstall gasket on
INSIDE of brew head
Clean spray disk
Check keypad, controller, power
board & solenoid
Repair, replace as needed
Turn water supply ON
Clean solenoid screen
Clean strainer
Replace filter element
Turn faucet valve ON
Disassemble faucet, clean
POSSIBLE CAUSE
Brewer unplugged or circuit
breaker tripped
Temperature adjusted too low
or set to OFF
Hi-Limit thermostat tripped
Damaged internal component or
wiring
Timer out of adjustment
Too many filter papers or wrong
filter paper
Brew chamber dispense hole
plugged
Spray gasket improperly
installed
Spray disk plugged
Damaged internal component
or wiring
Water supply OFF
Solenoid screen plugged
Water line strainer (if used)
plugged
Water filter (if used) plugged
Faucet valve turned OFF
Faucet plugged
SYMPTOM
Water won’t heat
Coffee level too high or low
Brew chamber overflows
Sprays water from brew head
No brew while faucet flows OK
No brew plus no flow from hot
water faucet
No flow from hot water faucet
Poor coffee quality
Keep brewer, airpots and servers clean. Install a taste and odor
filter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.
TROUBLESHOOTING SUGGESTIONS
12
642 75872 Owners Manual E.B.C. Airpot /Thermal