Bloomfield 9600 Single Cup Coffeemaker User Manual


 
OPERATION
7
A. START-UP
For initial start-up, or if the brewer has not been used for an
extended period of time:
Be sure the water supply is properly connected and the water
supply valve is turned
ON.
Be sure that TANK HEATER SWITCH is
OFF before connecting
brewer to electric power.
Be sure the WATER TANK IS FILLED.
IMPORTANT: Fill the water tank before energizing this brewer.
1. Connect brewer to electric power. Brewer will begin filling. When
solenoid closes, tank is full.
2. Place an empty container on the cup grid. Press the HOT WATER
DISPENSE BUTTON and dispense one cup of water.
Tank should refill. Discard water.
3. Press TANK HEATER SWITCH to
ON.
4. When READY light glows, brewer is ready to use.
IMPORTANT:
TANK MUST BE FULL
OF WATER BEFORE
CONNECTING BREWER
TO ELECTRIC POWER.
Heating elements will be
damaged if allowed to
operate without being
fully submerged in water.
Damage caused by
operating the brewer
without water in the tank
is NOT COVERED BY
WARRANTY.
See page 8 for setting
delivered water volumes
for VOLUME SELECTION
KEYS.
Fig. 4 Water Flow Diagram