ITEM
1.
a6.
8.
9.
a10.
a11.
12.
a15.
16.
18.
19.
22.
23.
28.
a31.
38.
40.
41.
42.
43.
44.
53.
56.
57.
58.
DESCRIPTION
NAMEPLATE
FIRE SUPPRESSION
AGENT TANK (1.5 gal.)
ADJUSTABLE (FRONT) LEG
RIGID (REAR) CASTER
MANUAL PULL STATION
FUSIBLE LINKS
LOWER REAR ACCESS
PANEL
DISCHARGE NOZZLE
GREASE BAFFLE
PRE-FILTER ASSEMBLY
HEPA/CHARCOAL FILTER
PACK
GREASE CUP
GREASE TROUGH
VENTILATOR EXHAUST
DUCT
STATUS INDICATOR
POWER CORD
FUSES
POWER CONTACTOR
BUILDING FIRE ALARM
RELAY
GROUND LUG
INTERLOCK TERMINAL
FILTER INTERLOCK
SWITCHES
VENTILATOR FAN
HOOD SIDE SHIELD
SIDE SPACERS
COMMENT
Gives manufacturer, make and model description. Also lists voltage
and amperage data.
Container for Ansulex™ Low-pH liquid fire suppression liquid.
Allows the unit to be leveled.
Allows the unit to be easily positioned by lifting the front of the unit
slightly.
Provides a means of manual activation of the fire suppression system.
PULL ONLY IN CASE OF FIRE!
Automatically activates fire suppression system in the event of fire on
the cooktop.
Allows access to Ansul® fire suppression agent tank (a6) and controls
also access to main power contactor (41).
Fire suppression media discharges here (2 places).
Extracts and drains most grease and moisture from the air flow.
Comprises the PRE-FILTER FRAME and a replaceable
PRE-FILTER. Stops larger particles of grease from reaching the
FILTER PACK for reduced maintenance costs.
Stops most grease and smoke particles. Also assists in some cooking
odor removal.
Collects grease/moisture drained from grease trough (23).
Directs grease/moisture removed by grease baffle to grease cup.
Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK
Displays status of fire suppression system (COCKED - FIRED) If
FIRED, a buzzer will sound continuously.
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
Provide over-current protection.
Energizes cooking appliances only while ventilator section is sensed
as operational.
Reports fire alarm condition to building fire management system.
Ground wire of power cord connects here.
Provides connection for shut-down control by building fire management
system.
Proper installation of grease baffle and filter pack close these switches
in ventilator sensor circuit.
Provides air movement for ventilation.
Required on left and right sides of hood. Factory installed.
Required to maintain 6" spacing from combustibles. Field installed.
FEATURES & OPERATING CONTROLS (continued)
VENTILATOR SECTION
3