Bosch Appliances HBN33 Microwave Oven User Manual


 
English 3
Preparation
Before you Begin
Tools and Parts Needed
Phillips head screwdriver
Measuring tape
Drill with bit (1/8")
Parts Included
Phillips head screws (6)
27” Appliances
General Information
Power Requirements The outlet must be properly grounded in accordance with all applicable codes.
Dimensions for 27” Wall-Mounted Units
25
1/2"
(648mm)
28
1/4"
(718mm)
27
"
(686mm)
24
13/16"
(630mm)
min. 4
3/4"
(121mm)
max. 31
3/8"
(797mm)
24
"
(610mm)
23
7/8"
(606mm)
22
"
(559mm)
29
1/16"
(738mm)
26
3/4"
(680mm)
Single Oven 27”
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4”
space between the side of the oven
and the wall/door.
For oven support, install 2x4’s
extending front to back flush with the
bottom and the side of the opening.
The supporting base must be well
secured to the floor/cabinet and level.
Note: The conduit box must be
installed either above or below the
unit. If the conduit box is installed
below the unit, a 2” diameter hole or
space is required between the back
wall and the right rear of the 2x4
supports.
The cabinet base must be flat and
capable of supporting a weight of at
least 210 lbs (95 kg).