Bosch Appliances SHE660 Dishwasher User Manual


 
30 _E
(762mm)
21 EE
(533mm)
Electrical Shock Hazard
To avoid electdcaJ shock, do not work on an
energized circuit. Doing so could resuJt in serious
injury or death. Onty qualified electricians should
perform electrical work. Do not attempt any work
on the dishwasher etectric suppty circuit until you
are certain the circuit is
de-energized.
Figure 4
Dishwasher E_ectrica_ Rating
Velts Amperes Watts
120 60 15 1,450
(max)
3" A,, 1
( 75mm ° lOOmm1.
3/8"- 1/2" _ .<
( 8mm- 13mm) I
Figure 5
Fire Hazard
To avoid a fire hazard, make sure electrical work
is properly installed. OnJy qualified electricians
shouJd perform eJectrical work.
Electrica! Supply
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shall be a
minimum #14 AWG copper wire rated at 75°C or higher.
Regardless of where the electrical supply cable enters the
enclosure, position the cable 21" (533mm) from the
enclosure's left side, as shown in Figure 4. Extend the
cable 30" (762mm) from the enclosure's back, as shown
in Figure 4.
Remove 3" =4" (75mm =lOOmm) of the cable's outer
casing, as shown in Figure 5, then remove 3/8" - 1/2"
(9 - 13mm) of insulation from each wire, as shown in
Figure 5.