New Buck Corporation 80ZC Cooktop User Manual


 
NOTE:
Finished
wall
must
be
2"
in
front
of
face
of
Z.C.
Cabinet
(without
hood
panell.
Singi. H
••
der
A Single Header
must
be used as
part
of
front Iraming, vertical
2"
....
·s
must
be turned flat.
WARNING!
Install
the
hearth
protector
only
as
specified.
The
hearth
extension
must
extend
a
minimum
of
16"
in
front
of
the
fireplace
opening
and
must
be
47
1/2"
wide
mini-
mum.
CAUTION!
Refer
to
chimney
manufacturers
instructions
for
assembly
and
disassembly
of
chimney
parts.
Be
sure
to
follow
chimney
instructions
for
proper
clearances
to
combusti-
bles
and
proper
air
spacing
required.
Doubl. H
••
der
-+1----
A Double
Header
must
be used
on
a
load
bearing wall. This
must
be
done
12" above
cabinet.
Chimney Cap
"Y~
.....
4-'::;"':~--
2"
x."
Siudding
//?~--
Chimney Pipe
FIGURE 7 EXTERIOR
ROOF
OR
CHASE
9