Bunn 41170.0001A Coffeemaker User Manual


 
Page 6
BREW LOCKOUT (YES/NO)
Setting to "YES" only allows brewing at or above the "SET READY" temp screen.
BREW LOCKOUT ?
NO DONE YES
BREW OZ A: 8.0
(-) DONE (+)
BREW METER A: 2
- +
BREW OZ. (LARGE) (1-16)
Adjust brew volume for "LARGE" button.
BREW METER (LARGE) (1-5)
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
BREW OZ. (SMALL) (1-16)
Adjust brew volume for "SMALL" button.
BREW METER (SMALL) (1-5)
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
BREW OZ B: 6.0
(-) DONE (+)
BREW METER B: 1
ENTER SERVICE #
NO DONE YES
ENTER SERVICE #
Program service phone number to be displayed anytime there is a fault message.
ENTER PASSWORD
User must enter a 3 digit number to access remainder of adjustments. If no
number has been pre programmed (0 0 0), then access is allowed.
SET PASSWORD
0 0 0
ENTER PASSWORD
0 0 0
SET TEMP: 200°
(-) DONE (+)
SET LANGUAGE ?
NO YES
UNITS
METRIC DONE ENG
SET PASSWORD (001-999)
Program any three digit number as a password.
LEVEL 2
SET LANGUAGE
Choose between English or Spanish.
UNITS
Choose between English or metric.
SET TEMP
Adjust tank temperature 185 to 205° F (85 to 96° C)
PROGRAM FUNCTIONS
SET READY
Sets the minimum temperature allowable to start a brew cycle. Range: (2° to
20° F) or (2° to 10° C) below the set temperature.
SET READY: 195°
(-) DONE (+)
HOT H2o LOCKOUT
Setting to "YES" will only allow dispensing of hot water at or above the "H2o
READY" temp screen.
HOT H2O LOCKOUT ?
NO DONE YES
CONTINUED
41170.1 050312
- +