Bunn OL Coffeemaker User Manual


 
Page 8
Problem
Equipment will not operate.
Brew cycle will not start.
Probable Cause
1. No power or incorrect voltage
1. No water
2. Water Strainer
3. Water Level Switch and Overflow
Safety Switch
Remedy
(A) Connect the brewer to the power
source.
(B) Check the terminal block for the
proper voltages.
(C) Check circuit breaker/fuse.
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer and check
for obstructions. Clear or replace.
Refer to Service - Water Level Switch
and Overflow Safety Switch for test-
ing procedures. See page 23.
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
All electric components have 120 volt ac voltage on their terminals. Shorting of terminals or the application
of external voltages may result in equipment failure.
Intermittent operation of electronic equipment is unlikely. Component failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times unless disconnected from the power source. Keep away from combustibles.
WARNING
Exercise extreme caution when servicing electrical equipment.
Disconnect the brewer from the power source when servicing, except when electrical tests are specified.
Follow recommended service procedures
Replace all protective shields or safety notices